<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>NA-CONNECT &#8211; Tubes Technologies</title>
	<atom:link href="https://tubes-technologies.com/en/categorie-produit/tank-accessories/merck-novaseptic-tank-accessories/na-connect-merck-novaseptic-tank-accessories/feed/" rel="self" type="application/rss+xml" />
	<link>https://tubes-technologies.com</link>
	<description>Transfert de fluides et gaz purs et équipements de cuves aseptiques</description>
	<lastBuildDate>Thu, 29 Oct 2026 10:34:51 +0000</lastBuildDate>
	<language>en-GB</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=7.1.4</generator>
	<item>
		<title>NA Connect® In-Line Clamp Millipore NovAseptic®</title>
		<link>https://tubes-technologies.com/en/produit/na-connect-in-line-clamp-millipore-novaseptic/</link>
					<comments>https://tubes-technologies.com/en/produit/na-connect-in-line-clamp-millipore-novaseptic/#respond</comments>
		
		<dc:creator><![CDATA[hello@inspire.cool]]></dc:creator>
		<pubDate>Wed, 28 Oct 2026 16:27:45 +0000</pubDate>
				<guid isPermaLink="false">https://tubes-technologies.com/?post_type=product&#038;p=8789</guid>

					<description><![CDATA[&#160; The in-line NA Connect® flange is a registered and protected trademark of Merck NovaSeptic®. &#160; &#160; NA Connect® stands for Novaseptic Connection! &#160; &#160; This flange, invented by Novaseptic®, makes it possible to position a clamp ferrule, clamp-connected instrumentation or a clamp sampling valve as close and as flush as possible on process piping. [&#8230;]]]></description>
										<content:encoded><![CDATA[<p>&nbsp;</p>
<p>The in-line NA Connect® flange is a registered and protected trademark of Merck NovaSeptic®.</p>
<p>&nbsp;</p>
<p>&nbsp;</p>
<p>NA Connect® stands for Novaseptic Connection!</p>
<p>&nbsp;</p>
<p>&nbsp;</p>
<p>This flange, invented by Novaseptic®, makes it possible to position a clamp ferrule, clamp-connected instrumentation or a clamp sampling valve as close and as flush as possible on process piping.</p>
<p>&nbsp;</p>
<p>&nbsp;</p>
<p>The in-line NA Connect flange minimises the gap between the clamp ferrule carrying the instrumentation and the flow line in the piping.</p>
<p>&nbsp;</p>
<p>&nbsp;</p>
<p>Made in France, it combines the following features:</p>
<p>&nbsp;</p>
<p>&nbsp;</p>
<p>Material:</p>
<ul>
<li style="list-style-type: none">
<ul>
<li style="list-style-type: none">
<ul>
<li style="list-style-type: none">
<ul>
<li>316L 1.4435BN2 using Ugitech raw stock</li>
</ul>
</li>
</ul>
</li>
</ul>
</li>
</ul>
<p>&nbsp;</p>
<ul>
<li style="list-style-type: none">
<ul>
<li style="list-style-type: none">
<ul>
<li style="list-style-type: none">
<ul>
<li>Available in Hastelloy C22, Al6Xn, 904l, Uranus B6</li>
</ul>
</li>
</ul>
</li>
</ul>
</li>
</ul>
<p>&nbsp;</p>
<ul>
<li style="list-style-type: none">
<ul>
<li style="list-style-type: none">
<ul>
<li style="list-style-type: none">
<ul>
<li>Pressure from -1 to 7 bar(g), temperature from -80°C to 200°C</li>
</ul>
</li>
</ul>
</li>
</ul>
</li>
</ul>
<p>&nbsp;</p>
<ul>
<li style="list-style-type: none">
<ul>
<li style="list-style-type: none">
<ul>
<li style="list-style-type: none">
<ul>
<li>Ra&lt;0.4µm, available with Ra&lt;0.4µm electropolished.</li>
</ul>
</li>
</ul>
</li>
</ul>
</li>
</ul>
<p>&nbsp;</p>
<p>&nbsp;</p>
<p>Dimensions:</p>
<p>&nbsp;</p>
<p>SMS on the instrumentation support</p>
<p>&nbsp;</p>
<p>ASME BPE on the process line</p>
<p>&nbsp;</p>
<p>Weld-end or clamp connection</p>
<p>&nbsp;</p>
<p>&nbsp;</p>
<p>&nbsp;</p>
<p>&nbsp;</p>
<p><span style="color: #333399"><strong><a style="color: #333399" title="Fiche technique NA Connect en ligne tri clamp Selon ASTM A270" href="https://tubes-technologies.com/wp-content/uploads/2026/08/3501.-NA-Connect-en-ligne-ASME-BPE-embouts-Tri-Clamp.xlsx" target="_blank" rel="noopener">In-line Tri Clamp NA Connect data sheet to ASME BPE</a></strong></span></p>
<p>&nbsp;</p>
<p>&nbsp;</p>
]]></content:encoded>
					
					<wfw:commentRss>https://tubes-technologies.com/en/produit/na-connect-in-line-clamp-millipore-novaseptic/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>NA Connect® In-Line Weld-End Millipore NovAseptic®</title>
		<link>https://tubes-technologies.com/en/produit/na-connect-in-line-weld-end-millipore-novaseptic/</link>
					<comments>https://tubes-technologies.com/en/produit/na-connect-in-line-weld-end-millipore-novaseptic/#respond</comments>
		
		<dc:creator><![CDATA[hello@inspire.cool]]></dc:creator>
		<pubDate>Wed, 28 Oct 2026 16:27:28 +0000</pubDate>
				<guid isPermaLink="false">https://tubes-technologies.com/?post_type=product&#038;p=8788</guid>

					<description><![CDATA[In-line weld-end NA Connect data sheet to ASME BPE &#160; The in-line NA Connect® flange is a registered and protected trademark of Merck NovaSeptic®. &#160; &#160; NA Connect® stands for Novaseptic Connection! &#160; &#160; This flange, invented by Novaseptic®, makes it possible to position a clamp ferrule, clamp-connected instrumentation or a clamp sampling valve as [&#8230;]]]></description>
										<content:encoded><![CDATA[<p><span style="color: #333399"><strong><a style="color: #333399" title="Fiche technique NA Connect en ligne Selon ASME BPE" href="https://tubes-technologies.com/wp-content/uploads/2026/08/3501.-NA-Connect-en-ligne-ASME-BPE-embouts-a-souder.xlsx" target="_blank" rel="noopener">In-line weld-end NA Connect data sheet to ASME BPE</a></strong></span></p>
<p>&nbsp;</p>
<p>The in-line NA Connect® flange is a registered and protected trademark of Merck NovaSeptic®.</p>
<p>&nbsp;</p>
<p>&nbsp;</p>
<p>NA Connect® stands for Novaseptic Connection!</p>
<p>&nbsp;</p>
<p>&nbsp;</p>
<p>This flange, invented by Novaseptic®, makes it possible to position a clamp ferrule, clamp-connected instrumentation or a clamp sampling valve as close and as flush as possible on process piping.</p>
<p>&nbsp;</p>
<p>&nbsp;</p>
<p>The in-line NA Connect flange minimises the gap between the clamp ferrule carrying the instrumentation and the flow line in the piping.</p>
<p>&nbsp;</p>
<p>&nbsp;</p>
<p>Made in France, it combines the following features:</p>
<p>&nbsp;</p>
<p>&nbsp;</p>
<p>Material:</p>
<ul>
<li style="list-style-type: none">
<ul>
<li style="list-style-type: none">
<ul>
<li style="list-style-type: none">
<ul>
<li>316L 1.4435BN2 using Ugitech raw stock</li>
</ul>
</li>
</ul>
</li>
</ul>
</li>
</ul>
<p>&nbsp;</p>
<ul>
<li style="list-style-type: none">
<ul>
<li style="list-style-type: none">
<ul>
<li style="list-style-type: none">
<ul>
<li>Available in Hastelloy C22, Al6Xn, 904l, Uranus B6</li>
</ul>
</li>
</ul>
</li>
</ul>
</li>
</ul>
<p>&nbsp;</p>
<ul>
<li style="list-style-type: none">
<ul>
<li style="list-style-type: none">
<ul>
<li style="list-style-type: none">
<ul>
<li>Pressure from -1 to 7 bar(g), temperature from -80°C to 200°C</li>
</ul>
</li>
</ul>
</li>
</ul>
</li>
</ul>
<p>&nbsp;</p>
<ul>
<li style="list-style-type: none">
<ul>
<li style="list-style-type: none">
<ul>
<li style="list-style-type: none">
<ul>
<li>Ra&lt;0.4µm, available with Ra&lt;0.4µm electropolished.</li>
</ul>
</li>
</ul>
</li>
</ul>
</li>
</ul>
<p>&nbsp;</p>
<p>&nbsp;</p>
<p>Dimensions:</p>
<p>&nbsp;</p>
<p>SMS on the instrumentation support</p>
<p>&nbsp;</p>
<p>ASME BPE on the process line</p>
<p>&nbsp;</p>
<p>Weld-end or clamp connection</p>
]]></content:encoded>
					
					<wfw:commentRss>https://tubes-technologies.com/en/produit/na-connect-in-line-weld-end-millipore-novaseptic/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>NA Connect® Millipore NovAseptic® Tank Flanges</title>
		<link>https://tubes-technologies.com/en/produit/na-connect-millipore-novaseptic-tank-flanges/</link>
					<comments>https://tubes-technologies.com/en/produit/na-connect-millipore-novaseptic-tank-flanges/#respond</comments>
		
		<dc:creator><![CDATA[hello@inspire.cool]]></dc:creator>
		<pubDate>Wed, 28 Oct 2026 16:27:12 +0000</pubDate>
				<guid isPermaLink="false">https://tubes-technologies.com/?post_type=product&#038;p=8787</guid>

					<description><![CDATA[NA Connect data sheet to ASME BPE &#160; NA Connect data sheet to ASTM A270 &#160; NA Connect data sheet to DIN1850 &#160; NA Connect data sheet to ISO1127 &#160; NA Connect data sheet to SMS3008 &#160; The in-line NA Connect® flange is a registered and protected trademark of Merck NovaSeptic®. &#160; &#160; NA Connect® [&#8230;]]]></description>
										<content:encoded><![CDATA[<p><span style="color: #333399"><strong><a style="color: #333399" title="Fiche technique NA Connect Selon ASME BPE" href="https://tubes-technologies.com/wp-content/uploads/2026/08/3500.-NA-Connect-selon-ASME-BPE.pdf" target="_blank" rel="noopener">NA Connect data sheet to ASME BPE</a></strong></span></p>
<p>&nbsp;</p>
<p><span style="color: #333399"><strong><a style="color: #333399" title="Fiche technique NA Connect Selon ASTM A270" href="https://tubes-technologies.com/wp-content/uploads/2026/08/3500.-NA-Connect-selon-ASTM-A270.pdf" target="_blank" rel="noopener">NA Connect data sheet to ASTM A270</a></strong></span></p>
<p>&nbsp;</p>
<p><span style="color: #333399"><strong><a style="color: #333399" title="Fiche technique NA Connect Selon DIN1850" href="https://tubes-technologies.com/wp-content/uploads/2026/08/3500.-NA-Connect-selon-DIN11850.pdf" target="_blank" rel="noopener">NA Connect data sheet to DIN1850</a></strong></span></p>
<p>&nbsp;</p>
<p><span style="color: #333399"><strong><a style="color: #333399" title="Fiche technique NA Connect Selon ISO1127" href="https://tubes-technologies.com/wp-content/uploads/2026/08/3500.-NA-Connect-selon-ISO1127.pdf" target="_blank" rel="noopener">NA Connect data sheet to ISO1127</a></strong></span></p>
<p>&nbsp;</p>
<p><span style="color: #333399"><strong><a style="color: #333399" title="Fiche technique NA Connect Selon SMS3008" href="https://tubes-technologies.com/wp-content/uploads/2026/08/3500.-NA-Connect-selon-SMS3008.pdf" target="_blank" rel="noopener">NA Connect data sheet to SMS3008</a></strong></span></p>
<p>&nbsp;</p>
<p>The in-line NA Connect® flange is a registered and protected trademark of Merck NovaSeptic®.</p>
<p>&nbsp;</p>
<p>&nbsp;</p>
<p>NA Connect® stands for Novaseptic Connection!</p>
<p>&nbsp;</p>
<p>&nbsp;</p>
<p>This flange, invented by Novaseptic®, makes it possible to position a clamp ferrule, clamp-connected instrumentation or a clamp sampling valve as close and as flush as possible on process piping.</p>
<p>&nbsp;</p>
<p>&nbsp;</p>
<p>The in-line NA Connect flange minimises the gap between the clamp ferrule carrying the instrumentation and the flow line in the piping.</p>
<p>&nbsp;</p>
<p>&nbsp;</p>
<p>Made in France, it combines the following features:</p>
<p>&nbsp;</p>
<p>&nbsp;</p>
<p>Material:</p>
<ul>
<li style="list-style-type: none">
<ul>
<li style="list-style-type: none">
<ul>
<li style="list-style-type: none">
<ul>
<li>316L 1.4435BN2 using Ugitech raw stock</li>
</ul>
</li>
</ul>
</li>
</ul>
</li>
</ul>
<p>&nbsp;</p>
<ul>
<li style="list-style-type: none">
<ul>
<li style="list-style-type: none">
<ul>
<li style="list-style-type: none">
<ul>
<li>Available in Hastelloy C22, Al6Xn, 904l, Uranus B6</li>
</ul>
</li>
</ul>
</li>
</ul>
</li>
</ul>
<p>&nbsp;</p>
<ul>
<li style="list-style-type: none">
<ul>
<li style="list-style-type: none">
<ul>
<li style="list-style-type: none">
<ul>
<li>Pressure from -1 to 7 bar(g), temperature from -80°C to 200°C</li>
</ul>
</li>
</ul>
</li>
</ul>
</li>
</ul>
<p>&nbsp;</p>
<ul>
<li style="list-style-type: none">
<ul>
<li style="list-style-type: none">
<ul>
<li style="list-style-type: none">
<ul>
<li>Ra&lt;0.4µm, available with Ra&lt;0.4µm electropolished.</li>
</ul>
</li>
</ul>
</li>
</ul>
</li>
</ul>
<p>&nbsp;</p>
<p>&nbsp;</p>
<p>Dimensions:</p>
<p>&nbsp;</p>
<p>SMS on the instrumentation support</p>
<p>&nbsp;</p>
<p>ASME BPE on the process line</p>
<p>&nbsp;</p>
<p>Weld-end or clamp connection</p>
]]></content:encoded>
					
					<wfw:commentRss>https://tubes-technologies.com/en/produit/na-connect-millipore-novaseptic-tank-flanges/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
	</channel>
</rss>
