PTFE FDA USP Class VI Clamp Gasket

On a tri-clamp connection, sealing is not provided by the clamp but by the gasket. The clamp sets the compression; the gasket turns it into a seal and absorbs the forces from the line. The choice of its material determines the allowable temperature, chemical compatibility and service life of the connection.

Solid PTFE offers the broadest chemical and thermal resistance in the range. Range from -73 °C to +260 °C. Its rigidity requires high tightening and it creeps under temperature variations.

 

Rubber Fab materials and chemical compatibility guide

 

Tubes Technologies gasket selection guide

 

Gasket dimensions data sheet

 

Rubberfab references, Type I gasket without lip

 

Rubberfab references, Type II gasket with lip

 

Guidelines for sanitary gasket materials

 

 

Solid PTFE tri-clamp gaskets, Type I and Type II

 

Virgin PTFE, -73 °C to +260 °C, without lip and with lip

 

Solid PTFE clamp gasket, available without lip (Type I) and with centring lip (Type II). Service range from -73 °C to +260 °C. Virtually total chemical inertness, compatible with almost all pharmaceutical products and aggressive chemicals. FDA and USP Class VI compliant. Diameters from 1/2″ to 12″. Low extractables, low absorption rate.

 

Where this material is the right choice, and where it is not

PTFE is the material of choice when cold flexibility and elastic memory are not required, and when the gasket stays in service for a long time on water as well as steam. Its chemical inertness makes it compatible with almost all pharmaceutical fluids and aggressive products that elastomers cannot withstand. Low extractables, low absorption, clean surface.

 

Its rigidity is the trade-off. Solid PTFE requires high tightening to seal, which calls for a clamp capable of delivering this compression without deforming. It creeps and exhibits cold flow under repeated temperature variations, which causes leaks at delta T on thermally cycled lines. For intensive SIP with pronounced cycles, a unitised gasket such as Tuf-Flex or Tuf-Steel holds up better over time.

 

Type I and Type II: the lip changes installation

Type I, or Type B, is a flat gasket without lip. It is centred by hand in the groove of the two ferrules. This is the most common and least expensive version.

 

Type II, or Type A, has a centring lip that fits into the inside diameter of the ferrule. The gasket positions itself, cannot shift while the clamp is being closed, and alignment of its inner face with the flow path is guaranteed. On lines where a shifted flat gasket creates retention, or on hard-to-reach installations, the lip eliminates the risk of poor centring.

 

The choice between the two does not depend on the material, which is identical, but on the centring requirement at the installation point. Both versions cover the same temperature range and the same chemical compatibility.

 

Material properties

Characteristic Value
Material Virgin PTFE
Service temperature -73 °C to +260 °C (-100 °F to 500 °F)
Creep Susceptible to creep and cold flow under thermal cycling
Tightening High tightening force required
Compliance FDA, USP Class VI, depending on size (see appendix)
Versions Type I without lip, Type II with centring lip

 

 

The temperature range and chemical compatibilities come from the manufacturer’s data. Detailed fluid-by-fluid chemical information is provided in the materials guide and the compatibility sheet, available for download.

 

Chemical resistance table

 

Dimensions

 

Standardised dimensions, common to all tri-clamp gasket materials. The gasket outside diameter corresponds to the ferrule face, the inside diameter to the flow path. A gasket whose inside diameter protrudes into the flow path creates retention; a gasket that is too small opens a crevice.

 

Size Gasket ID (mm) Gasket OD (mm) Ferrule flange A (mm) Tube DN
1/2″ – 3/4″ to be completed to be completed 25,4 DN8 to DN15
1″ 22,9 / 0.900″ 50,4 / 1.984″ 50,5 DN25
1 1/2″ 35,6 / 1.400″ 50,4 / 1.984″ 50,5 DN40
2″ 48,3 / 1.900″ 63,9 / 2.515″ 64 DN50
2 1/2″ 61,0 / 2.400″ 77,5 / 3.050″ 77,5 DN65
3″ 73,7 / 2.900″ 90,9 / 3.579″ 91 DN65
4″ 98,3 / 3.869″ 118,9 / 4.682″ 119 DN100
6″ 147,8 / 5.817″ 165,3 / 6.507″ 167 DN150

 

 

Millimetre conversions are for guidance only, based on the manufacturer’s dimensions in inches. The complete clamp, ferrule and tube correspondence table is available for download.

The gasket: the sensitive link in the clamp fitting

The quality of a clamp connection depends on three elements: the gasket, the clamp and pipe alignment. The gasket provides the seal and at the same time absorbs the torsional forces transmitted by the line. This dual role is the weak point of the clamp fitting.

 

A misaligned or stressed section makes the gasket work constantly, causing wear and then premature tearing. Excessive tightening pushes the gasket into the flow path and creates a dead leg. Compression is achieved at the torque specified for the clamp, never by feel. The gasket is the consumable part of the connection: it is replaced, not salvaged.

 

This material compared with others

A gasket material is chosen based on temperature, fluid, dismantling frequency, regulatory requirements and cleaning method. Here is what sets the main materials apart.

 

Material What it offers Its limitations
EPDM (and silicone) Very flexible, seals even on irregular surfaces, easy to install, economical Limited temperature, sensitive to solvents and oxidisers, does not withstand oils
FKM Viton Solvents, oils, acids, up to 204 °C, ozone-resistant Less effective with strong oxidisers, less flexible, more expensive
Solid PTFE Exceptional chemical and thermal resistance Very rigid, high tightening, possible creep
EPDM/PTFE enveloped Inert PTFE face, flexible EPDM core, good compromise Creep if overtightened, EPDM core limited in temperature
Gylon 3504 Flexible, low tightening, creep-resistant, -260 to +268 °C Flat without lip, care required during installation, blue
Tuf-Flex PTFE bonded to EPDM, crush-resistant, WFI More expensive, strong oxidisers to be checked
Tuf-Steel PTFE + 316L stainless steel, creep-resistant, -196 to +288 °C Expensive, reserved for demanding applications

 

 

Each material has a dedicated data sheet with its service ranges, compliance and detailed chemical compatibilities.

 

Frequently asked questions

PTFE or elastomer?

PTFE for chemical inertness and temperature resistance, when the line is not subject to large thermal variations. An elastomer, EPDM or FKM, when elastic memory and flexibility are needed, particularly on slightly misaligned faces or under thermal cycling where PTFE creeps.

 

Type I or Type II?

Type I, without lip, for standard installation. Type II, with centring lip, when the gasket must position itself and not shift, particularly where access is difficult or at points where shifting creates retention. Same material, same range; only the centring differs.

 

How do I choose the size?

On the outside diameter of the ferrule, like the clamp. The gasket inside diameter must be flush with the flow path without protruding. The correspondence table gives the equivalence between size, ferrule and tube.

 

Which compliance applies for pharmaceuticals?

FDA and USP Class VI compliance is stated by the manufacturer for sizes 1″ to 4″. Outside this range, it must be verified before being recorded in a file. The exact certification must appear on the material certificate for the batch delivered.